Check of level of liquid of the power steering
In difference from the steering mechanism of usual type, in the rack transfer equipped with the hydraulic booster working liquid which starts needing replacement eventually is used.
Location of the tank of GUR liquid is shown on accompanying illustrations in Settings and routine maintenance of the car. The tank is equipped with the screw cover which is turning off counterclockwise.
|
1. Several times turn a steering wheel from an emphasis against the stop then establish forward wheels of the car in rectilinear situation and to kill the engine. 2. In order to avoid hit of dirt in hydraulic system wipe a cover and a surface of the tank pure rags. 3. Rotating counterclockwise, uncover with the tank equipped with the measuring probe. To the touch estimate temperature moistening liquid probe edge.
|
4a. Carefully wipe an edge of the probe pure nevorsyashcheysya rags, screw a cover into place, then again remove it and visually determine the liquid level which has to depending on weather conditions be in limits of the corresponding range by the probe (address to an accompanying illustration). |
|
4b. On some models the level of working liquid can be estimated through translucent walls of its tank (address to an accompanying illustration). Try not to allow a GUR liquid level exit out of limits of the lower bound of admissible range. |
5. If necessary liquid is added directly in the tank through a mouth of the last by means of a funnel. Use working liquid only of the recommended grade. 6. If need for adjustment of level of liquid arises regularly and often, check the steering pump, a case of rack transfer, and also all connecting lines of a hydraulic path of system of GUR and their nipple connections for existence of signs of leaks. 7. At the idling engine remember the level of working liquid in a tank. 8. Stop the engine and check distinction in GUR liquid levels at the working and stopped engine. If liquid level considerably changed (more, than on 5 mm), it is necessary to pump over system of GUR. |
|
|