3-3-15-zamena-bloka-upravleniya-ehlektronnogo-pereklyuchatelya-kpp.html
3.3.15. Replacement of the control unit of the check point electronic switch
NOTE
At control unit replacement before demontazhy make dumping of data by the TECH2 device.
|
Disconnect clips of the storage battery.
Release and disconnect the socket of a plait of wires 1 and 3.
Wring out outside fixing ledges 2 and take out forward the check point control unit.
NOTE
Depending on option of the engine and a check point differently calibrated check points control units are applied. At replacement of the check point control unit use the corresponding new block. It is ordered in the service center.
|
Fix the check point control unit in the holder.
Insert and fix 2 sockets of plaits of wires.
Attach clips of the storage battery.
Program volatile memories.
NOTE
At control unit replacement, after control unit installation, execute the appropriate program by means of the device.
|
|