2-10-13-snyatie-i-ustanovka-datchika-massovogo-raskhoda-vozdukha.html
2.10.13. Removal and installation of the sensor of a mass consumption of airRemoval
Open a cowl
Remove the sensor of a mass consumption of air.
For this purpose disconnect the socket of a plait of wires and 2 hoses of an air inlet.
Remove 2 collars.
Installation
Establish the sensor of a mass consumption of air.
Connect an air inlet hose.
Tighten 2 collars the moment of 3.5 N · m.
Connect the socket of a plait of wires.