8-2-10-snyatie-i-ustanovka-kapota.html
8.2.10. Removal and cowl installationRemoval
Dismantle a cowl.
At hinge replacement: dismantle a water repeller.
Uncover the block of the relay of the module of management of electronic systems of a body.
Installation
At replacement of a cover of a cowl, establish isolation.
Adjust a cowl to a wing.
Adjustment of a gap 3 is carried out in points of screwing up 1, and adjustment on height – in points of screwing up 2.
1–Points of screwing up of a cowl.
2–Points of screwing up of the hinge of a cowl.
Flatten the rivet end by means of nippers 2.
Adjust locking.
Adjusting size (X) = 40–45 mm.
To Zakontrita a round nut in the following sequence: 5 round nuts, 6 twisted spring, the 7th washer, 8 directing pin.
The moment of an inhaling of a round nut and directing pin – 22 N · m.
NOTE
Grease directing pin.
|
Removal and installation of a forward door
Removal
Disconnect the socket of a plait of wires.
Dismantle a door.
Unscrew the fixing screw of fastening of the tape door limiter.
Dismantle tightening plugs of the door hinge.
NOTE
To greasing of tightening plugs apply greasing of a high pressure (number of a detail 90 510 336 / number according to the catalog 19 48 606).
|
Installation
Establish a door.
If necessary adjust a forward door.
NOTE
Observe adjusting gaps.
Adjusting gaps
NOTE